HANNA, TDS meter, model TDS-1

HANNA Total Disolved Solids (TDS) meter, model TDS-1

Water contains a variety of minerals and salts such as carbonates, bicarbonates, chlorides and nitrate. TDS is the parameter that measures the total sum of all of these compounds.
TDS 1 is a simple and affordable tester for TDS measurements. Due to its internal sensor, TDS measurements are automatically compensated for temperature variations. Calibration can be performed in one point with a trimmer.
The tester is supplied with a cap that protects the probe when it is not in use. Batteries can be easily replaced.
Light and small, TDS 1 is an ideal pocket meter to perform quick TDS measurements.

Specifications :
Range :0 to 999 ppm (mg/L)
Resolution : 1 ppm (mg/L)
Accuracy : ±2% F.S.
Calibration Solution : HI 70080P (optional)
Calibration     : manual, 1 point, through trimmer
Temperature Compensation : Automatic, 5 to 50°C (41 to 122°F)
Battery Type / Life : 4 x 1.5V / approx. 150 hours
Environment : 0 to 50°C (32 to 122°F); RH max 95%
Dimensions : 150 x 30 x 21 mm (5.9 x 1.2 x 0.8″)
Weight : 70 g (2.5 oz.)

Harga Rp. call , Harga tidak termasuk PPN, franko Yogyakarta, berlaku 1 Januari 2015. Harga dapat berubah sewaktu-waktu.

Download brosur klik di sini

ask for detail

HANNA, COD Meter, Model : HI 83214

HANNA COD Meter HI83214

HANNA COD Meter HI83214

HANNA, COD Meter, Model : HI 83214

COD Meter and Multiparameter Photometer for Wastewater Analysis

specifications :

Light Source : tungsten lamps with narrow-band interference filters
Light Detector : silicon photocell
Power Supply : external 12 VDC power adapter or built-in rechargeable battery
Auto-off : after 10 min. of non-use in measuring mode; after 1 hour of non-use in calibration mode with last reading reminder
Dimensions : 235 x 200 x 110 mm (9.2 x 7.87 x 4.33″)
Weight : 0.9 Kg (2 lbs.)
Environment : 0 to 50°C (32 to 122°F); RH max 90% non-condensing

Harga Rp. call,- , Harga tidak termasuk PPN franko Yogyakarta, berlaku Juli. Harga dapat berubah sewaktu-waktu.

ask for detail

HANNA, Photometer, Model : HI 83206

HANNA HI83206

HI 83206

HANNA, Photometer, Model : HI 83206

Multiparameter Photometer for Environmental Testing

specifications :

Light Source : up to 5 tungsten lamps with different narrow band interference filters.
Light Detector : silicon photocell
Power Supply : external 12 VDC power adapter or built-in rechargeable battery
Environment : 0 to 50°C (32 to 122°F); max 90% RH non-condensing
Dimensions : 235 x 200 x 110 mm (9.2 x 7.87 x 4.33″)
Weight : 0.9 Kg (2 lbs.)

Harga :  call , Harga tidak termasuk PPN franko Yogyakarta, Harga dapat berubah sewaktu-waktu.

ask for detail

HANNA, Photometer, Model : HI 83225

HANNA HI83225

HANNA HI83225

HANNA, Photometer, Model : HI 83225

Nutrient Analysis Photometer for Greenhouses and Hydroponics, Advanced

specifications :

Light Source : up to 5 tungsten lamps with different narrow band interference filters.
Light Detector : silicon photocell
Power Supply : external 12 VDC power adapter or built-in rechargeable battery
Environment : 0 to 50°C (32 to 122°F); max 90% RH non-condensing
Dimensions : 235 x 200 x 110 mm (9.2 x 7.87 x 4.33″)
Weight : 0.9 Kg (2 lbs.)

Harga : call , Harga tidak termasuk PPN franko Yogyakarta, Harga dapat berubah sewaktu-waktu.

ask for detail

HANNA, COD Meter, Model : HI 83099

HANNA COD Meter HI83099

HANNA COD Meter HI83099

HANNA, COD Meter, Model : HI 83099

COD and Multiparameter Bench Photometer

spesifications :

Light Source : tungsten lamps with narrow-band interference filters
Light Detection : silicon photocell
Power Supply : external 12 VDC power adapter or built-in rechargeable battery
Auto-off : after 10 min of non-use in measuring mode; after 1 hour of non-use in calibration mode with last reading reminder
Environment : 0 to 50°C (32 to 122°F); max 90% RH non-condensing
Dimensions : 235 x 200 x 110 mm (9.2 x 7.87 x 4.33)
Weight : 0.9 Kg (2 lbs.)

Harga : call , Harga tidak termasuk PPN franko Yogyakarta, Harga dapat berubah sewaktu-waktu.

ask for detail

HANNA, COD Reactor, Model : HI 839800

HANNA COD Reactor HI839800

HANNA COD Reactor HI839800

HANNA, COD Reactor, Model : HI 839899

COD REACTOR and Test Tube Heater 2008 Series

specifications:

Temperature of Reaction :105°C or 150°C (221°F or 302°F)
Temperature Stability :±0.5°C (±0.9°F)
Temperature Range :-10°C to 160°C (14°F to 320°F)
Accuracy :±2°C (±3.6°F)
Capacity :25 vials (dia 16 x 100 mm), one receptacle for a stainless steel reference thermometer

(more…)

HANNA, DO Meter, Model : HI 9142

HANNA DO Meter HI9142

HANNA DO Meter HI9142

HANNA, DO Meter, Model : HI 9142

DO Meter

specifications :

Range : 0.0 to 19.9 mg/L (ppm)
Resolution : 0.1 mg/L
Accuracy : ±1.5% FS
Typical EMC : ±0.8 mg/L
Deviation : with 4 m cable probe
Calibration : Manual, 1 or 2 point (zero and slope)
Temperature Compensation :  Automatic, 0 to 30°C  (32 to 86°F)

HANNA, DO Meter, Model : HI 9146

HANNA DO Meter HI9146

HI 9146 indogama

HANNA, DO Meter, Model : HI 9146

DO Meter

specifications :

Range : 0.00 to 45.00 mg/L O2
0.0 to 300 %O2
0.0 to 50.0 °C
Resolution : 0.01 mg/L O2
0.1 %O2
0.1 °C
Accuracy (@25°C/77°F) : ±1.5% Full Scale mg/L O2
±1.5% Full Scale %O2
±0.5 °C

HANNA, DO Meter, Model : HI 9147

HANNA DO Meter HI 9147

HI 9147 indogama

HANNA, DO Meter, Model : HI 9147

DO Meter

specifications :

Range : 0.0 to 50.0 mg/L (ppm) O2
0 to 600 % O2
-5.0 to 50.0°C
Resolution : 0.1 mg/L or 1% (O2) / 0.1°C
Accuracy : ±1% of reading (O2) / ±0.2°C
Typical EMC Deviation : ±2% of reading (O2) / ±1°C
Calibration : Manual, in saturated air
Temperature Compensation :  Automatic, from -5 to 50°C (23 to 122°F)
Salinity Compensation : 0 to 51 g/L (resolution 1 g/L)

HANNA, DO Meter, Model : HI 93732N

HANNA HI 93732N

HI 93732N

Hanna, DO Meter, Model : HI 93732N

DO Meter hi 93732n

specifications :
Range :   0.0 to 10.0 mg/L (ppm)
Resolution :  0.1 mg/L
Accuracy :  ±0.2 mg/L ± 3% of reading
Typical EMC : ±0.1 mg/L
Deviation
Light  : Source Light Emitting Diode @ 470 nm
Method : Adaptation of the Standard Methods for
the Examination of Water and Wastewater
(18th edition), azide modified Winkler
method. The reaction between dissolved
oxygen and the reagent causes a yellow
tint in the sample. hi 93732n